Battery Tester HBT4000 Series
Model | Resistance Resolution | Resistance Range | Resistance Range | Voltage Resolution | Voltage Range | Voltage Accuracy | Interface |
HBT4561A | 0.1μΩ | 0~3.9kΩ | 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3900Ω) | 1μV | 0~160V | 士0.01%rdg土3dgt | RS232/485 USB LAN IO ANALOGOUTFUT |
HBT4561H | 0.1μΩ | 0~3.9kΩ | 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3900Ω) | 1μV | 0~160V | 士0.01%rdg土3dgt | RS232/485 USB LAN IO ANALOGOUTPUT GPIB |
HBT4562A | 0.1μΩ | 0~3.9kΩ | 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3900Ω) | 1μV | 0~260V | 士0.01%rdg土3dgt | RS232/485 USB LAN IO ANALOGOUTFUT |
HBT4562H | 0.1μΩ | 0~3.9kΩ | 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3900Ω) | 1μV | 0~260V | 士0.01%rdg土3dgt | RS232/485 USB LAN IO ANALOGOUTPUT GPIB |
HBT4563A | 0.1μΩ | 0~3.9kΩ | 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3900Ω) | 1μV | 0~410V | 士0.01%rdg土3dgt | RS232/485 USB LAN IO ANALOGOUTFUT |
HBT4563H | 0.1μΩ | 0~3.9kΩ | 士0.5%rdg土10dgt(3mΩ),士0.5%rdg土5dgt(30mΩ-3900Ω) | 1μV | 0~410V | 士0.01%rdg土3dgt | RS232/485 USB LAN IO ANALOGOUTPUT GPIB |
Model |
HBT4561A/H |
HBT4562A/H |
HBT4563A/H |
|||
Resistance |
Range |
3mΩ/30mΩ/300mΩ/3Ω/30Ω/300Ω/3900Ω |
||||
Measuring Range |
0~3.9kΩ |
|||||
Min. Resolution |
0.1μΩ |
|||||
Voltage |
Range |
6V/60V/160V |
6V/60V/260V |
6V/60V/410V |
||
Measuring Range |
0-160V |
0-260V |
0-410V |
|||
Min. Resolution |
1μV |
|||||
Rating Input Voltage |
DC土160VDC |
DC土260VDC |
DC土410VDC |
|||
Current Frequency |
1KHz |
|||||
Input Impedance |
3mΩ~3900Ω 1MΩ |
|||||
Open Terminal Voltage |
3mΩ~3900Ω 12V peak |
|||||
Detect Abnormal Test Results and Display (Contact detection) |
Detection content: Abnormal connection between SOURCE HIGH and LOW Abnormal connection display between SENSE HIGH LOW: [------] |
|||||
Sampling |
Sample Rate |
FAST/MEDIUM/SLOW(3rd gear) |
||||
Sample Time |
Function |
Frequency |
FAST |
MEDIUM |
SLOW |
|
ΩV |
50Hz/60Hz |
60ms |
300ms |
600ms |
||
Ω |
50Hz/60Hz |
40ms |
200ms |
400ms |
||
V |
50Hz/60Hz |
40ms |
200ms |
400ms |
||
Time |
Response Time |
Measurement response time: approximately 5ms |
||||
Total Measurement Time |
Time required for the entire measurement: sampling time+response time |
|||||
Comparator Function Module |
Comparator Function |
ON/OFF (shared resistance and voltage) |
||||
Comparator Settings |
Comparator mode: HIGH · LOW/REF ·% Upper and lower limit values: 0-3000 (resistance)/0-410 (voltage) Reference value: 0-3000 (resistance)/0-410 (voltage) Precent(%): 0.00%~99.99% (% range set to+/- universal) Buzzer: Close/HL/IN/BT1/BT2 Comp mode: AUTO/Manual |
|||||
Compare |
Compare Result: Hi/IN/Lo (independent judgment of resistance and voltage) PASS/UNPASS judgment: Compare the resistance judgment result with the voltage judgment result AND operation, followed by PASS/UNPASS output (EXT I/O output) Test outlier determination: OF Hi determination -OF Lo determination Test Exception - No Judgment (No Judgment) |
|||||
Absolute Function |
Under this function, even if the battery polarity is reversed, it can be compared based on absolute values |
|||||
Average Function |
Output the average measurement value, which can reduce the deviation of the displayed value. The average frequency is 1, 2, 4, and 8 times |
|||||
Delay Time |
0-9999 ms |
|||||
Calibrate |
Voltage calibration/resistance calibration, used to compensate for bias voltage or gain drift within this instrument |
|||||
Adjustable Zero Range |
Resistance measurement: -1000 to 1000 count values Voltage measurement: -1000~1000 count values (i.e. zero range is less than or equal to ± 1000 dgt.) |
|||||
Trigger |
Int/Ext/Man |
|||||
Save |
ON/OFF/Clear, the measured values can be saved to the USB flash drive through EXT I/O, buttons, and commands |
|||||
Statistics |
Statistical Operations |
ON/OFF/Clear |
||||
Operational Content |
Average, Max, Min, Parent Standard Deviation, Sample Standard Deviation, Procedure Ability Index (Shift), Procedure Ability Index (Deviation) |
|||||
Arithmetic Trigger |
Perform statistical calculations on measured values through EXT I/O, buttons, and commands |
|||||
Measurement Settings Saving and Reading |
Function |
Can save and read measurement settings |
||||
Save Settings |
Test function, resistance range, voltage range, automatic range setting, using rate, trigger source, delay setting, average setting, comparator settings, statistical operation settings |
|||||
Keytone |
ON/OFF |
|||||
Communication Interface |
HBT4000 series: standard RS232/485, USB, LAN, IO, ANALOGOUTFUT, optional GPIB |
Model |
HBT4561A/H |
HBT4562A/H |
HBT4563A/H |
|||
Resistance |
Range |
3mΩ/30mΩ/300mΩ/3Ω/30Ω/300Ω/3900Ω |
||||
Measuring Range |
0~3.9kΩ |
|||||
Min. Resolution |
0.1μΩ |
|||||
Voltage |
Range |
6V/60V/160V |
6V/60V/260V |
6V/60V/410V |
||
Measuring Range |
0-160V |
0-260V |
0-410V |
|||
Min. Resolution |
1μV |
|||||
Rating Input Voltage |
DC土160VDC |
DC土260VDC |
DC土410VDC |
|||
Current Frequency |
1KHz |
|||||
Input Impedance |
3mΩ~3900Ω 1MΩ |
|||||
Open Terminal Voltage |
3mΩ~3900Ω 12V peak |
|||||
Detect Abnormal Test Results and Display (Contact detection) |
Detection content: Abnormal connection between SOURCE HIGH and LOW Abnormal connection display between SENSE HIGH LOW: [------] |
|||||
Sampling |
Sample Rate |
FAST/MEDIUM/SLOW(3rd gear) |
||||
Sample Time |
Function |
Frequency |
FAST |
MEDIUM |
SLOW |
|
ΩV |
50Hz/60Hz |
60ms |
300ms |
600ms |
||
Ω |
50Hz/60Hz |
40ms |
200ms |
400ms |
||
V |
50Hz/60Hz |
40ms |
200ms |
400ms |
||
Time |
Response Time |
Measurement response time: approximately 5ms |
||||
Total Measurement Time |
Time required for the entire measurement: sampling time+response time |
|||||
Comparator Function Module |
Comparator Function |
ON/OFF (shared resistance and voltage) |
||||
Comparator Settings |
Comparator mode: HIGH · LOW/REF ·% Upper and lower limit values: 0-3000 (resistance)/0-410 (voltage) Reference value: 0-3000 (resistance)/0-410 (voltage) Precent(%): 0.00%~99.99% (% range set to+/- universal) Buzzer: Close/HL/IN/BT1/BT2 Comp mode: AUTO/Manual |
|||||
Compare |
Compare Result: Hi/IN/Lo (independent judgment of resistance and voltage) PASS/UNPASS judgment: Compare the resistance judgment result with the voltage judgment result AND operation, followed by PASS/UNPASS output (EXT I/O output) Test outlier determination: OF Hi determination -OF Lo determination Test Exception - No Judgment (No Judgment) |
|||||
Absolute Function |
Under this function, even if the battery polarity is reversed, it can be compared based on absolute values |
|||||
Average Function |
Output the average measurement value, which can reduce the deviation of the displayed value. The average frequency is 1, 2, 4, and 8 times |
|||||
Delay Time |
0-9999 ms |
|||||
Calibrate |
Voltage calibration/resistance calibration, used to compensate for bias voltage or gain drift within this instrument |
|||||
Adjustable Zero Range |
Resistance measurement: -1000 to 1000 count values Voltage measurement: -1000~1000 count values (i.e. zero range is less than or equal to ± 1000 dgt.) |
|||||
Trigger |
Int/Ext/Man |
|||||
Save |
ON/OFF/Clear, the measured values can be saved to the USB flash drive through EXT I/O, buttons, and commands |
|||||
Statistics |
Statistical Operations |
ON/OFF/Clear |
||||
Operational Content |
Average, Max, Min, Parent Standard Deviation, Sample Standard Deviation, Procedure Ability Index (Shift), Procedure Ability Index (Deviation) |
|||||
Arithmetic Trigger |
Perform statistical calculations on measured values through EXT I/O, buttons, and commands |
|||||
Measurement Settings Saving and Reading |
Function |
Can save and read measurement settings |
||||
Save Settings |
Test function, resistance range, voltage range, automatic range setting, using rate, trigger source, delay setting, average setting, comparator settings, statistical operation settings |
|||||
Keytone |
ON/OFF |
|||||
Communication Interface |
HBT4000 series: standard RS232/485, USB, LAN, IO, ANALOGOUTFUT, optional GPIB |